滲漏報警器是用于油浸式電力變壓器用復合管式水冷卻器發(fā)生滲漏故障時發(fā)出報警信號的裝置。
Hence the seepage enunciator is the device that issues the alarm when being used oil the soaking type power transformer type water-cooling with the multiple-unit tube but ware to occur the seepage to hinder
1.型號含義 1. The model meaning
L B 0 2
第2次設計 2nd design
報警器 Enunciator
滲漏 Seepage
2.工作條件
2. The work condition
2.1.工作環(huán)境溫度0℃~55℃。
2.1. 0℃~55℃'s work environment
temperature.
2.2.當空氣溫度為25℃時,
濕度不大于90%。
2.2.When the air temperature degree
is 25 ℃s high above in the sky ,
humidity is not very in 90%.
2.3.海拔高度不超過2000米。
2.3. The elevation height does not surpass 2000 meters.
2.4.周圍無劇烈震動和顛簸的場所。 圖1
2.4. Surrounding inacute shake and place jolting. The picture 1
3.技術參數(shù)
3. The technology parameter
3.1.產品外形尺寸:φ76×140。
3.1. The product OAD : φ76×140.
3.2.產品重量:1.5㎏。
3.2. Product weight : 1.5㎏.
3.3.滲漏液體容積為不超過50㎝3時報警。
3.3. The seepage liquid volume is at 40 o'clocks to report to the police.
3.4.接點容量:220V,AC 3A,DC 0.5A。
3.5.The contact capacity:220V,AC 3A,DC 0.5A.
4.結構特點和工作原理
4. Structure characteristic and work principle
4.1.本產品由法蘭、殼體、浮筒、永久磁鐵、隔板、干簧接點開關、接線盒等組成。參見圖1。
4.1. This product is by flange and shell aspect , float , permanent magnet , screen and dry reed contact open Guan forms by the wiring box etc See also the picture 1.
4.2.當冷卻器發(fā)生滲漏時,滲漏的液體流到殼體中,當滲漏的液體達到一定容量時,浮筒上升并帶動永久磁鐵上升,使干簧接點開關動作發(fā)出報警信號。
4.3.The liquid of seepage flows into the shell aspect when the chiller occurs the seepage , and when liquid when the seepage achieves the fixed capacity , the float moves upward and drives the permanent magnet moving upward , and makes futilely reed contact open close the action and issue the alarm Installation.
5.安裝
5. Installation
5.1.安裝尺寸參見圖1。
5.1. Installing the size sees also the picture 1.
5.2.滲漏報警器應安裝在復合管式水冷卻器的水管和油管之間的空腔的下部,這樣可使水管滲漏的水和/或油管滲漏的油能順利地流到滲漏報警器中。
5.2. The seepage enunciator should be installed in the multiple-unit tube type water-cooling but lower part of cavity betwee