99热久久这里只有精品,99久久人妻精品免费二区,成人综合亚洲欧美一区,国产成人精品亚洲一区,久久国产亚洲精品赲碰热

進口CIRS線形測試模塊

  • 發(fā)布時間:2022-07-19 14:19:41,加入時間:2012年07月03日(距今4827天)
  • 地址:中國»廣東»深圳:深圳市龍華新區(qū)觀瀾大道75號田背花園E單元806
  • 公司:深圳市灣邊貿易有限公司,用戶等級:普通會員 已認證
  • 聯系:張雪鳳,手機:13714972229 微信:wanbian-B 電話:0755-86216601 QQ:1191737095

深圳市灣邊貿易有限公司代理進口美國 Computerized Imaging Reference Systems 公司模體: CIRS 055模體-三維超聲校準模塊, CIRS 055A模體-3D線形測試模塊,CIRS 044模體,CIRS 049A-彈性模體。

   美國原裝進口質量保證!價格更優(yōu)。  

For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements.

Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability.

Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods.

The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.The basic standard for ultrasound quality assurance.

The series of ultrasound phantoms, unlike human subjects or random scannable materials, offers a reliable medium which contains specific, known test objects for repeatable qualitative assessment of ultrasound scanner performance over time. This phantom is constructed from the patented solid elastic material Zerdine®.

Zerdine®, unlike other phantom materials on the market, is not affected by changes in temperature. It can be subjected to boiling or freezing conditions without sustaining significant damage. Zerdine® is also more elastic than other materials and allows more pressure to be applied to the scanning surface without subsequent damage to the material. At normal or room temperatures, the Zerdine® material found in the Model 054 will accurately simulate the ultrasound characteristics found in human liver tissue.

Designed to allow for axial resolution, lateral response width, uniformity, dead zone measurements, depth of visualization, high and low contrast mass imaging, and distance calibration.

Fully complies with all requirements and recommendation of the AIUM and ACR.

聯系我時請說明來自志趣網,謝謝!

免責申明:志趣網所展示的信息由用戶自行提供,其真實性、合法性、準確性由信息發(fā)布人負責。使用本網站的所有用戶須接受并遵守法律法規(guī)。志趣網不提供任何保證,并不承擔任何法律責任。 志趣網建議您交易小心謹慎。